NOR 4082 High-Level and Overfill Alarm System
The reed-switch inner tube can be replaced without removing the installed unit from the tank top or gas-freeing the tank. Only the tip is replaced, so the new design is independent of the original probe length. Spare sensors can be cut to suit different alarm levels.
Each high-level alarm operates independently. The cabinet and alarm panel identify the tank and level for every alarm. The PLC can operate as a network slave using MODBUS RTU, BITBUS or TIWAY.
Technical specifications
Cabinet: cold-rolled, corrosion-protected sheet steel with an epoxy finish. Standard colour: RAL 7035 grey. Customer-specified colours are available. The cabinet and panel provide an alarm overview for each tank.
Communications: hardwired signals, RS-485 serial interface, TCP or fieldbus.
Power supply: 110/230 VAC, 50/60 Hz at 10 A, maximum 600 VA.
Environment: ambient temperature −25 °C to +70 °C, relative humidity up to 100% throughout the applicable temperature range, vibration 0.7 g.
Type approval: DNV GL.
Alarms: multistage level alarms and low-flow alarms.
Switch types
NOR 4082-S (single stage): one fixed alarm point per tank, at 98% or the specified overfill alarm level.
NOR 4082-D (dual stage): two independently operating fixed alarm points at 95% and 98%.
NOR 4082-T (triple stage): three independently operating fixed alarm points at 95%, 98% and 99%.